Global Generators Ltd


Address

Xenon Park, Worcester Avenue, Doncaster, DN2 4NB

Phone

+44 1302 700200

WhatsApp

+44 1302 700200

Email

enquiries@global-generators.com


Generators


  • All Generators
  • Diesel Generators
  • Silent Generators
  • Open Generators
  • 3 Phase Generators
  • Single Phase Generators
  • 50Hz Generators
  • Standby Generators
  • Generators for Homes

Brands


  • Cummins

Company


  • About Us
  • Blog
  • Contact Us

Power


  • 10 kVA
  • 20 kVA
  • 50 kVA
  • 100 kVA
  • 200 kVA
  • 500 kVA
  • 1000 kVA

© Global Generators Ltd . All rights reserved.  |  Registration number: 17168598

Privacy Policy | Cookie Policy | Site Map

Global Generators Logo
Generators
Info
Contact
All Generators
Diesel
SilentOpen
3 PhaseSingle Phase
50Hz
Cummins
StandbyFor Homes
10 kVA15 kVA20 kVA25 kVA30 kVA40 kVA50 kVA60 kVA90 kVA
100 kVA150 kVA200 kVA250 kVA300 kVA400 kVA500 kVA600 kVA700 kVA
800 kVA900 kVA1000 kVA1500 kVA2000 kVA2500 kVA3000 kVA
10 kW15 kW20 kW25 kW30 kW40 kW50 kW70 kW80 kW
100 kW150 kW200 kW250 kW300 kW400 kW500 kW600 kW700 kW
800 kW900 kW1000 kW1500 kW2000 kW

About UsBlog

Contact






2026
  1. Home
  2. Generators
  3. Cummins
  4. C1675D5A

1675 kVA Cummins Open Diesel Generator

Cummins C1675D5A | 1675 kVA Open Diesel Generator
* Image(s) are for illustration purposes only, actual configuration may differ slightly.

Cummins C1675D5A

1675 kVA Open Diesel Generator

Standby1675 kVA
1340 kW
Prime1500 kVA
1200 kW
EngineCummins KTA50-GS8

AlternatorStamford S7LVD

Control PanelCummins PowerCommand 3.3

Frequency50Hz

Phase3

Voltage400V

Fuel TankN/A
View Full Data Sheet

POA

SpecsSpecifications
Documents
Delivery
ContactContact Us

Cummins C1675D5A Diesel Generator Set

The Cummins C1675D5A is a high-capacity industrial diesel generator engineered to deliver dependable power for critical applications where reliability, efficiency, and performance are essential. Offering 1675 kVA standby power and 1500 kVA prime power, this robust generator set is designed for large-scale facilities, infrastructure projects, industrial operations, and mission-critical environments that demand uninterrupted power availability.

1675 kVA Generator for Critical Standby Power Applications

When utility power failures are simply not an option, the Cummins C1675D5A provides a dependable standby power solution capable of supporting substantial electrical loads. With a standby rating of 1675 kVA (1340 kW), this generator is ideally suited to hospitals, data centres, manufacturing facilities, airports, utilities, commercial buildings, and major infrastructure projects.

Its advanced engineering ensures rapid response during mains power interruptions, helping organisations maintain operational continuity and protect sensitive equipment from costly downtime. For businesses requiring a 1340 kW diesel generator that can be relied upon during emergencies, the C1675D5A delivers the performance expected from one of the world's most respected power generation manufacturers.

1500 kVA Prime Power Generator for Continuous Operation

Beyond emergency backup duties, the Cummins C1675D5A also excels as a prime power generator. With a prime rating of 1500 kVA (1200 kW), it is capable of supplying power continuously in locations where grid access is unavailable or unreliable.

This makes the generator an excellent choice for:

  • Remote mining operations
  • Oil and gas facilities
  • Large construction projects
  • Utility support applications
  • Manufacturing plants
  • Temporary power installations
  • Infrastructure development projects

For organisations searching for a 1500 kVA generator that can sustain varying loads over extended periods, the C1675D5A offers the durability and operational efficiency required for demanding environments.

Powered by the Proven Cummins KTA50 Engine

At the heart of this industrial generator lies the renowned Cummins KTA50 engine platform. Developed specifically for heavy-duty power generation applications, this V16 diesel engine is recognised worldwide for its durability, reliability, and long service life.

The turbocharged and aftercooled engine design enables efficient power production while maintaining excellent load acceptance characteristics. This allows the generator to respond effectively to sudden load changes commonly experienced in critical facilities and industrial operations.

The engine's robust construction and proven operating history make the C1675D5A particularly attractive to organisations seeking long-term reliability and lower lifetime operating costs. Its electronic governing system contributes to stable frequency control and dependable power quality across varying operating conditions.

High Performance Power Generation for Large-Scale Facilities

Large electrical systems require more than simply high output. They demand consistent performance, voltage stability, and dependable operation under changing load profiles.

The Cummins C1675D5A has been engineered to support these requirements across a wide range of applications. Whether powering a data centre during a utility outage, supporting manufacturing processes, or providing temporary power for major infrastructure works, the generator is designed to maintain stable performance under demanding conditions.

Its heavy-duty alternator options provide flexibility for both low-voltage and medium-voltage installations, making the generator suitable for a broad range of industrial and commercial power generation projects worldwide.

Designed for Global Industrial Applications

Many organisations operating internationally require generator solutions that can perform reliably in diverse environmental conditions. The C1675D5A has been developed with this requirement in mind.

Its integrated cooling system is designed to operate effectively in challenging ambient temperatures, while the advanced air handling and exhaust systems help maintain reliable engine performance under demanding operating conditions.

As a result, this diesel genset is frequently considered for applications including:

  • Data centre backup power
  • Healthcare facilities
  • Water treatment plants
  • Telecommunications infrastructure
  • Distribution centres
  • Industrial processing facilities
  • Energy and utility projects
  • Commercial developments

Its versatility makes it a strong option for both permanent installations and large-scale temporary power deployments.

Fuel Efficiency and Operational Economy

For operators managing substantial power requirements, fuel consumption plays an important role in total operating costs. The Cummins C1675D5A has been engineered to deliver an effective balance between performance and fuel efficiency, helping organisations optimise operating expenditure while maintaining dependable power availability.

The combination of advanced engine technology, electronic control systems, and efficient combustion characteristics enables the generator to perform effectively across a broad load range. This flexibility is particularly valuable for facilities where power demand fluctuates throughout daily operations.

For businesses evaluating large diesel generators for long-term operation, the ability to balance output capability with fuel economy can contribute significantly to overall project value.

Built for Reliability in Mission-Critical Environments

Reliability remains one of the most important considerations when selecting a generator of this size. Facilities that depend on uninterrupted electrical supply cannot afford unexpected equipment failures.

The Cummins C1675D5A benefits from decades of Cummins engineering expertise and is designed to meet the expectations of critical power users around the world. The generator incorporates proven technologies and heavy-duty components intended to support dependable operation throughout its service life.

This focus on reliability makes the generator particularly well suited to environments where uptime is essential, including healthcare facilities, financial institutions, transport infrastructure, and large-scale industrial operations.

Flexible Installation Options

Every project presents unique installation requirements. To support a wide range of applications, the Cummins C1675D5A is available in both open and enclosed configurations.

This flexibility allows project designers, consulting engineers, and facility operators to select a configuration that aligns with site requirements, environmental conditions, acoustic considerations, and operational objectives.

Whether installed within a dedicated generator plant room or deployed as part of an outdoor power generation system, the C1675D5A can be integrated into comprehensive standby or prime power solutions.

Why Choose the Cummins C1675D5A?

Selecting a large industrial generator is a significant investment, and buyers often prioritise proven performance, global support, and long-term dependability.

The Cummins C1675D5A offers several compelling advantages:

  • 1675 kVA standby power capability
  • 1340 kW emergency backup capacity
  • 1500 kVA prime power output
  • 1200 kW continuous operational performance
  • Proven Cummins KTA50 engine platform
  • Excellent load acceptance characteristics
  • Suitable for critical and industrial applications
  • Flexible voltage and alternator configurations
  • Global parts and service support network
  • Trusted Cummins engineering and reliability

For organisations seeking a powerful diesel generator capable of supporting large-scale electrical demands, the Cummins C1675D5A delivers a combination of performance, durability, and operational confidence that makes it an outstanding choice for both standby and prime power applications.

Generators Similar to the Cummins C1675D5A

Cummins C1250D5AB

Cummins C1250D5AB

Cummins C1250D5AB

Standby1250 kVA

Prime1125 kVA
EngineCummins
TypeOpen
Voltage400V
Made InIndia

POA

Cummins C1400D5

Cummins C1400D5

Cummins C1400D5

Standby1400 kVA

Prime1250 kVA
EngineCummins
TypeOpen

Power Output

Standby (ESP) Rating1675 kVA
1340 kW

Prime (PRP) Rating1500 kVA
1200 kW

Frequency50Hz

Phase3

Voltage400V

Amps Per Phase2421

Generator Set

ConfigurationOpen Type

AlternatorStamford S7LVD

Control PanelCummins PowerCommand 3.3

Dimensions
Length5779mmWidth2040mmHeight2518mm

Weight
Dry10137kgWet10293kg

Output ConnectionNone

Engine

EngineCummins KTA50-GS8

RPM1500

Engine GovernorElectronic

Emissions StandardUnregulated

Radiator Ambient Temp.40°C

Fuel

Fuel TypeDiesel

Fuel Tank CapacityN/A

Consumption309 Litres/hour*

AutonomyN/A

* at 100% prime rated load

Warranty

Standby Applications2 years or 500 hours

Prime Applications1 year unlimited hours
Cummins Generator Warranty Statement
Voltage
400V
Made InUK

POA

Cummins C1760D5

Cummins C1760D5

Cummins C1760D5

Standby1760 kVA

Prime1600 kVA
EngineCummins
TypeOpen
Voltage400V
Made InIndia

POA

Cummins C1760D5e

Cummins C1760D5e

Cummins C1760D5e

Standby1760 kVA

Prime1600 kVA
EngineCummins
TypeOpen
Voltage400V
Made InUK

POA